Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.109
Filtrar
1.
J Appl Lab Med ; 8(4): 713-725, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37018046

RESUMO

BACKGROUND: Several laboratory techniques for anti double-stranded (ds) DNA detection in systemic lupus erythematosus (SLE) are available, with variable diagnostic performance. We aimed to evaluate anti-dsDNA's diagnostic performance by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (EIA). METHODS: We conducted a single-center retrospective (2015 to 2020) study. Patients with anti-dsDNA tests by IIF and EIA were included. We evaluated the indications, applications, concordance, positive predictive value (PPV) of anti-dsDNA to confirm SLE diagnosis or flares, and associations of disease manifestations with positivity with each technique. RESULTS: A total of 1368 reports of anti-dsDNA tests by IIF and EIA and the corresponding medical records of the patients were analyzed. The main indication for anti-dsDNA testing was to help in the diagnosis of SLE in 890 (65%) of the samples, and the main application after obtaining the results was SLE exclusion in 782 (57.2%) cases. The combination with the highest frequency was the negativity result by both techniques in 801 (58.5%) cases (Cohen kappa 0.57). Both methods were positive in 300 patients with SLE (Cohen kappa 0.42). The PPVs of anti-dsDNA tests to confirm diagnosis/flare was 79.64% (95% CI, 75.35-83.35) by EIA, 78.75% (95% CI, 74.27-82.62) by IIF, and 82% (95% CI, 77.26-85.93) when both were positive. CONCLUSIONS: Anti-dsDNA detection by IIF and EIA are complementary and may indicate different clinical patterns in patients with SLE. The detection of anti-dsDNA antibodies by both techniques has a higher PPV than either separately for confirming SLE diagnosis or flares. These results highlight the need for evaluating both methods in clinical practice.


Assuntos
Anticorpos Antinucleares , Lúpus Eritematoso Sistêmico , Humanos , Ensaio de Imunoadsorção Enzimática/normas , Técnica Indireta de Fluorescência para Anticorpo/normas , Lúpus Eritematoso Sistêmico/diagnóstico , Estudos Retrospectivos , Anticorpos Antinucleares/análise , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Análise de Regressão
2.
J Immunol ; 208(6): 1500-1508, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35228262

RESUMO

Oral fluids offer a noninvasive sampling method for the detection of Abs. Quantification of IgA and IgG Abs in saliva allows studies of the mucosal and systemic immune response after natural infection or vaccination. We developed and validated an enzyme immunoassay (EIA) to detect and quantify salivary IgA and IgG Abs against the prefusion-stabilized form of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein expressed in suspension-adapted HEK-293 cells. Normalization against total Ab isotype was performed to account for specimen differences, such as collection time and sample volume. Saliva samples collected from 187 SARS-CoV-2 confirmed cases enrolled in 2 cohorts and 373 prepandemic saliva samples were tested. The sensitivity of both EIAs was high (IgA, 95.5%; IgG, 89.7%) without compromising specificity (IgA, 99%; IgG, 97%). No cross-reactivity with endemic coronaviruses was observed. The limit of detection for SARS-CoV-2 salivary IgA and IgG assays were 1.98 ng/ml and 0.30 ng/ml, respectively. Salivary IgA and IgG Abs were detected earlier in patients with mild COVID-19 symptoms than in severe cases. However, severe cases showed higher salivary Ab titers than those with a mild infection. Salivary IgA titers quickly decreased after 6 wk in mild cases but remained detectable until at least week 10 in severe cases. Salivary IgG titers remained high for all patients, regardless of disease severity. In conclusion, EIAs for both IgA and IgG had high specificity and sensitivity for the confirmation of current or recent SARS-CoV-2 infections and evaluation of the IgA and IgG immune response.


Assuntos
Anticorpos Antivirais/metabolismo , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina A/metabolismo , Imunoglobulina G/metabolismo , SARS-CoV-2/fisiologia , Saliva/metabolismo , Adolescente , Adulto , Idoso , Doenças Assintomáticas , Criança , Pré-Escolar , Progressão da Doença , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Lactente , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Pandemias , Padrões de Referência , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto Jovem
4.
Bioengineered ; 13(1): 876-883, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34968171

RESUMO

This research has developed a method for rapid detection of SARS-CoV-2 N protein on a paper-based microfluidic chip. The chitosan-glutaraldehyde cross-linking method is used to fix the coated antibody, and the sandwich enzyme-linked immunosorbent method is used to achieve the specific detection of the target antigen. The system studied the influence of coating antibody concentration and enzyme-labeled antibody concentration on target antigen detection. According to the average gray value measured under different N protein concentrations, the standard curve of the method was established and the sensitivity was tested, and its linear regression was obtained. The equation is y = 9.8286x+137.6, R2 = 0.9772 > 0.90, which shows a high degree of fit. When the concentration of coating antibody and enzyme-labeled antibody were 1 µg/mL and 2 µg/mL, P > 0.05, the difference was not statistically significant, so the lower concentration of 1 µg/mL was chosen as the coating antibody concentration. The results show that the minimum concentration of N protein that can be detected by this method is 8 µg/mL, and the minimum concentration of coating antibody and enzyme-labeled antibody is 1 µg/mL, which has the characteristics of high sensitivity and good repeatability.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/instrumentação , Proteínas do Nucleocapsídeo de Coronavírus/análise , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Dispositivos Lab-On-A-Chip , SARS-CoV-2/química , SARS-CoV-2/imunologia , Anticorpos Antivirais/imunologia , Engenharia Biomédica , COVID-19/diagnóstico , COVID-19/imunologia , COVID-19/virologia , Teste Sorológico para COVID-19/métodos , Teste Sorológico para COVID-19/normas , Proteínas do Nucleocapsídeo de Coronavírus/normas , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Dispositivos Lab-On-A-Chip/normas , Dispositivos Lab-On-A-Chip/estatística & dados numéricos , Procedimentos Analíticos em Microchip/métodos , Procedimentos Analíticos em Microchip/normas , Procedimentos Analíticos em Microchip/estatística & dados numéricos , Papel , Fosfoproteínas/análise , Fosfoproteínas/imunologia , Fosfoproteínas/normas
5.
Sci Rep ; 11(1): 23699, 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34880307

RESUMO

Dengue, caused by the dengue virus (DENV) is a significant vector-borne disease. In absence of a specific treatment and vaccine, dengue is becoming a rising threat to public health. Currently, control of dengue mainly focuses on the surveillance of the mosquito vectors. Improved surveillance methods for DENV in mosquito populations would be highly beneficial to the public health. However, current methods of DENV detection in mosquitoes requires specialized equipment and expensive reagents and highly trained personnel. As an alternative, commercially available dengue NS1 antigen ELISA kits could be used for detection of DENV infection in Aedes aegypti mosquitoes. In this study, we explored the utility of commercially available Dengue NS1 antigen kit (J. Mitra & Co. Pvt. Ltd) for the detection of recombinant dengue virus-2 (rDENV-2) NS1 protein and serum of dengue infected patient spiked with Ae. aegypti mosquito pools. The kit was found to be highly sensitive and specific towards detection of all serotypes of DENV. Further, it could detect as low as 750 femto gram rDENV-2 NS1 protein. It was also observed that rDENV-2 NS1 antigen spiked with blood-fed and unfed mosquito pools could be detected. In addition, the kit also detected dengue infected patient serum spiked with Ae. aegypti mosquito pools. Overall, the Dengue NS1 antigen kit displayed high sensitivity towards detection of recombinant as well as serum NS1 protein spiked with Ae. aegypti mosquito pools and could be considered for the dengue virus surveillance after a field evaluation in Ae. aegypti mosquitoes.


Assuntos
Aedes/virologia , Antígenos Virais/imunologia , Vírus da Dengue/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Mosquitos Vetores/virologia , Proteínas não Estruturais Virais/imunologia , Aedes/imunologia , Animais , Dengue/diagnóstico , Dengue/imunologia , Dengue/transmissão , Dengue/virologia , Vírus da Dengue/classificação , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Mosquitos Vetores/imunologia , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Sorogrupo
6.
Sci Rep ; 11(1): 23682, 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34880361

RESUMO

Human immunodeficiency virus-1 (HIV-1) persistence in the presence of antiretroviral therapy (ART) has halted the development of curative strategies. Measuring HIV persistence is complex due to the low frequency of cells containing virus in vivo. Most of the commercially available assays to date measure nucleic acid. These assays have the advantage of being highly sensitive and allow for the analysis of sequence diversity, intactness of the HIV genome or evaluation of diverse RNA species. However, these assays are limited in evaluating translational competent viral reservoirs. In here, we developed an ultrasensitive p24 ELISA that uses the Simoa planar array technology that can detect HIV-1 virions and HIV-1 infected cell with limit of detection similar to nucleic acid assays. Furthermore, the assay is optimized to measure very low levels of p24 in different biological fluids without a major loss of sensitivity or reproducibility. Our results demonstrate that the 'homebrew' planar p24 ELISA immunoassay is a broadly applicable new tool to evaluate HIV persistence in diverse biological fluids and cells.


Assuntos
Ensaio de Imunoadsorção Enzimática , Proteína do Núcleo p24 do HIV/metabolismo , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/metabolismo , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Proteína do Núcleo p24 do HIV/imunologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Molecules ; 26(23)2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34885683

RESUMO

Early detection of any preeclampsia biomarkers may lower the risk of mortality, both for a mother and a child. Our study focuses on techniques for preeclampsia biomarker identification by comparing the results of a method using liquid chromatography mass spectrometry in multiple reaction monitoring mode (LC-MS/MS) with those by the enzyme-linked immunosorbent assay (ELISA) test, as well as by comparing the obtained results with clinical data. In the proposed LC-MS/MS method a tryptic digest peptide charge derivatization strategy was used as a tool for sensitive detection of podocin, i.e., a previously discovered preeclampsia biomarker present in urine samples from pregnant women. Urine samples from pregnant women with diagnosed preeclampsia were collected at different stages of pregnancy and from healthy subjects, and then were analyzed by ELISA test and the proposed method with LC-MS/MS. Charge derivatization of the ε amino group of C-terminal lysine residues in tryptic digests by 2,4,6-triphenylpyrylium salt was performed to increase the ionization efficiency in the LC-MS/MS mode. Podocin was identified at the early stage of pregnancy, while its detection using an ELISA test was not possible. The protocol for urine sample preparation was optimized. Our results show that the proposed method by LC-MS/MS in combination with peptide charge derivatization, provides an ultrasensitive tool for diagnosis of preeclampsia, and provides earlier detection than a clinical diagnosis or ELISA test. The proposed solution may revolutionize medical diagnostics.


Assuntos
Biomarcadores/química , Diagnóstico Precoce , Peptídeos/química , Pré-Eclâmpsia/diagnóstico , Adulto , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Espectrometria de Massas , Peptídeos/isolamento & purificação , Pré-Eclâmpsia/metabolismo , Pré-Eclâmpsia/patologia , Gravidez , Espectrometria de Massas em Tandem
8.
Am J Trop Med Hyg ; 106(1): 156-159, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34818625

RESUMO

Point-of-care (POC) tests to detect SARS-CoV-2 antibodies offer quick assessment of serostatus after natural infection or vaccination. We compared the field performance of the BioMedomics COVID-19 IgM/IgG Rapid Antibody Test against an ELISA in 303 participants enrolled in a SARS-CoV-2 household cohort study. The rapid antibody test was easily implemented with consistent interpretation across 14 users in a variety of field settings. Compared with ELISA, detection of seroconversion lagged by 5 to 10 days. However, it retained a sensitivity of 90% (160/177, 95% confidence interval [CI] 85-94%) and specificity of 100% (43/43, 95% CI 92-100%) for those tested 3 to 5 weeks after symptom onset. Sensitivity was diminished among those with asymptomatic infection (74% [14/19], 95% CI 49-91%) and early in infection (45% [29/64], 95% CI 33-58%). When used appropriately, rapid antibody tests offer a convenient way to detect symptomatic infections during convalescence.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática , Testes Imediatos , SARS-CoV-2/imunologia , COVID-19/imunologia , Estudos de Coortes , Ensaio de Imunoadsorção Enzimática/normas , Características da Família , Humanos , Testes Imediatos/normas , SARS-CoV-2/isolamento & purificação
9.
Sci Rep ; 11(1): 19785, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34611273

RESUMO

In the present study, we developed a genus-specific rGroEL1-524 IgM-ELISA assay for use in screening diagnosis of suspected leptospirosis among acute undifferentiated febrile illness patients during acute fever. The diagnostic accuracies of the rGroEL1-524 IgM-ELISA, commercial Panbio IgM-ELISA, and Virion-Serion Classic IgG-ELISA were evaluated using 133 Thai leptospirosis sera and 210 controls. Sensitivities were 91.7%, 59.6%, and 17.7% for acute infection, and the specificities were 92.6%, 90.2%, and 88.3% for the non-leptospirosis control, respectively. The rGroEL1-524 IgM-ELISA had high sensitivity, at 92.3% and 91.7%, among culture-positive and MAT-negative cases at 1-3 days post-onset of symptoms (DPO1-3), respectively. Impaired specificity on scrub typhus was found, possibly from antibody cross-reaction to ortholog GroEL. Commercial Panbio IgM-ELISA had sensitivities at DPO1-3 of 30.8% and 41.7% for culture-positive and MAT-negative cases whereas Virion-Serion IgG-ELISA showed sensitivities of 5.9% and 13.3%, respectively. The rGroEL1-524 IgM-ELISA could be useful as a screening test for early diagnosis. The performance of the commercial ELISA suggests the applicability of IgM-ELISA for diagnosis, while IgG-ELISA is useful for seroprevalence surveys. However, confirmation by reference tests is recommended.


Assuntos
Chaperonina 60/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Imunoglobulina M/imunologia , Leptospirose/diagnóstico , Leptospirose/epidemiologia , Kit de Reagentes para Diagnóstico , Anticorpos Antibacterianos/imunologia , Epitopos/imunologia , Humanos , Leptospira/imunologia , Programas de Rastreamento , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Tailândia/epidemiologia
10.
Parasit Vectors ; 14(1): 473, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34526109

RESUMO

BACKGROUND: In characterizing malaria epidemiology, measuring mosquito infectiousness informs the entomological inoculation rate, an important metric of malaria transmission. PCR-based methods have been touted as more sensitive than the current "gold-standard" circumsporozoite (CSP) ELISA. Wider application of PCR-based methods has been limited by lack of specificity for the infectious sporozoite stage. We compared a PCR method for detecting the parasite's mitochondrial (mt) cytochrome oxidase I (COX-I) gene with ELISA for detecting circumsporozoite protein for identification of different life stages of the parasite during development within a mosquito. METHODS: A PCR-based method targeting the Plasmodium mt COX-I gene was compared with the CSP ELISA method to assess infectivity in Anopheles arabiensis colony mosquitoes fed on blood from patients infected with Plasmodium vivax. Mosquitoes were tested at six post-infection time points (days 0.5, 1, 6, 9, 12, 15). The head and thorax and the abdomen for each specimen were tested separately with each method. Agreement between methods at each infection stage was measured using Cohen's kappa measure of test association. RESULTS: Infection status of mosquitoes was assessed in approximately 90 head/thorax and 90 abdomen segments at each time point; in total, 538 head/thorax and 534 abdomen segments were tested. In mosquitoes bisected after 0.5, 1, and 6 days post-infection (dpi), the mt COX-I PCR detected Plasmodium DNA in both the abdomen (88, 78, and 67%, respectively) and head/thorax segments (69, 60, and 44%, respectively), whilst CSP ELISA detected sporozoites in only one abdomen on day 6 post-infection. PCR was also more sensitive than ELISA for detection of Plasmodium in mosquitoes bisected after 9, 12, and 15 dpi in both the head and thorax and abdomen. There was fair agreement between methods for time points 9-15 dpi (κ = 0.312, 95% CI: 0.230-0.394). CONCLUSIONS: The mt COX-I PCR is a highly sensitive, robust method for detecting Plasmodium DNA in mosquitoes, but its limited Plasmodium life-stage specificity cannot be overcome by bisection of the head and thorax from the abdomen prior to PCR. Thus, the mt COX-I PCR is a poor candidate for identifying infectious mosquitoes.


Assuntos
Anopheles/parasitologia , Ensaio de Imunoadsorção Enzimática/normas , Estágios do Ciclo de Vida/genética , Plasmodium vivax/genética , Reação em Cadeia da Polimerase/normas , Esporozoítos/genética , Animais , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Plasmodium vivax/imunologia , Reação em Cadeia da Polimerase/métodos , Esporozoítos/imunologia
11.
J Microbiol Methods ; 189: 106317, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34474104

RESUMO

Avian mycoplasmosis, mainly caused by Mycoplasma gallisepticum (MG) and Mycoplasma synoviae (MS) is an economically important disease of the poultry industry. The present study was aimed to develop whole cell based indirect-ELISA (i-ELISA) and DOT blot assay (DOT-ELISA) as rapid, sensitive, specific and economical sero-detection tests for MG and MS. A total of 306 blood samples were collected from birds slaughtered at local meat shops of different districts of Haryana, India to detect MG and MS antibodies. Sonicated antigens prepared from freshly grown culture of MG and MS were used to develop i-ELISA and DOT blot assay. In i-ELISA, 50.32% and 61.76% serum samples were found to be positive for MG and MS antibodies, respectively. However in DOT blot assay, 41.83% and 53.92% serum samples were found positive for MG and MS antibodies, respectively. The relative diagnostic sensitivity and specificity of DOT-ELISA were measured considering i-ELISA as a reference test. The relative diagnostic sensitivity of the DOT blot assay was found to be 69.48% and 82.01%; whereas relative diagnostic specificity was 86.18% and 91.45% for the detection of MG and MS antibodies, respectively. The developed serological assays may be used as rapid and economical diagnostic tools for large scale screening of poultry sera for MG and MS antibodies.


Assuntos
Anticorpos Antibacterianos/sangue , Ensaio de Imunoadsorção Enzimática/normas , Infecções por Mycoplasma/diagnóstico , Infecções por Mycoplasma/veterinária , Mycoplasma gallisepticum/imunologia , Mycoplasma synoviae/imunologia , Doenças das Aves Domésticas/diagnóstico , Animais , Galinhas/imunologia , Galinhas/microbiologia , Ensaio de Imunoadsorção Enzimática/métodos , Immunoblotting/métodos , Índia , Aves Domésticas/imunologia , Aves Domésticas/microbiologia , Doenças das Aves Domésticas/microbiologia , Sensibilidade e Especificidade
12.
Front Immunol ; 12: 635701, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34489923

RESUMO

Serological testing is a powerful tool in epidemiological studies for understanding viral circulation and assessing the effectiveness of virus control measures, as is the case of SARS-CoV-2, the pathogenic agent of COVID-19. Immunoassays can quantitatively reveal the concentration of antiviral antibodies. The assessment of antiviral antibody titers may provide information on virus exposure, and changes in IgG levels are also indicative of a reduction in viral circulation. In this work, we describe a serological study for the evaluation of antiviral IgG and IgM antibodies and their correlation with antiviral activity. The serological assay for IgG detection used two SARS-CoV-2 proteins as antigens, the nucleocapsid N protein and the 3CL protease. Cross-reactivity tests in animals have shown high selectivity for detection of antiviral antibodies, using both the N and 3CL antigens. Using samples of human serum from individuals previously diagnosed by PCR for COVID-19, we observed high sensitivity of the ELISA assay. Serological results with human samples also suggest that the combination of higher titers of antiviral IgG antibodies to different antigen targets may be associated with greater neutralization activity, which can be enhanced in the presence of antiviral IgM antibodies.


Assuntos
Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/prevenção & controle , Vigilância Imunológica , SARS-CoV-2/imunologia , Animais , Anticorpos Antivirais/sangue , Antígenos Virais/imunologia , COVID-19/epidemiologia , COVID-19/imunologia , Teste Sorológico para COVID-19/normas , Reações Cruzadas , Vírus da Dengue/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Camundongos , Camundongos Endogâmicos BALB C , Sensibilidade e Especificidade , Zika virus/imunologia
13.
J Immunol Res ; 2021: 9942605, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34514003

RESUMO

The diagnosis and monitoring of cancer have been facilitated by discovering tumor "biomarkers" and methods to detect their presence. Yet, for certain cancers, we still lack sensitive and specific biomarkers or the means to quantify subtle concentration changes successfully. The identification of new biomarkers of disease and improving the sensitivity of detection will remain key to changing clinical outcomes. Patient liquid biopsies (serum and plasma) are the most easily obtained sources for noninvasive analysis of proteins that tumor cells release directly and via extracellular microvesicles and tumor shedding. Therefore, an emphasis on creating reliable assays using serum/plasma and "direct, in-solution" ELISA approaches has built an industry centered on patient protein biomarker analysis. A need for improved dynamic range and automation has resulted in the application of ELISA principles to paramagnetic beads with chemiluminescent or fluorescent detection. In the clinical testing lab, chemiluminescent paramagnetic assays are run on automated machines that test a single analyte, minimize technical variation, and are not limited by serum sample volumes. This differs slightly from the R&D setting, where serum samples are often limiting; therefore, multiplexing antibodies to test multiple biomarkers in low serum volumes may be preferred. This review summarizes the development of historical biomarker "standards", paramagnetic particle assay principles, chemiluminescent or fluorescent biomarker detection advancements, and multiplexing for sensitive detection of novel serum biomarkers.


Assuntos
Biomarcadores Tumorais , Biópsia Líquida/métodos , Biópsia Líquida/normas , Neoplasias/diagnóstico , Neoplasias/etiologia , Automação , Biomarcadores Tumorais/sangue , Colorimetria/métodos , Colorimetria/normas , Gerenciamento Clínico , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Medições Luminescentes/métodos , Medições Luminescentes/normas , Neoplasias/sangue , Curva ROC , Sensibilidade e Especificidade
14.
J Alzheimers Dis ; 83(3): 1367-1377, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34420976

RESUMO

BACKGROUND: An N-terminal octapeptide cleavage of the cystatin C protein was discovered by mass spectrometry when cerebrospinal fluid (CSF) was stored at -20°C for 3 months, which did not occur when CSF was stored at -80°C. OBJECTIVE: The aim was to develop an immunoassay as quality assessment tool to detect this -20°C cleavage of cystatin C in CSF and support Alzheimer's disease research. METHODS: A specific monoclonal antibody and a double indirect sandwich ELISA were developed: one assay quantifies the octapeptide uncleaved protein specifically and the other quantifies the total cystatin C present in the biological fluid (both cleaved and uncleaved forms). The ratio of these concentrations was calculated to assess the extent of cleavage of cystatin C. The novel ELISA was validated and applied in a short-term (up to 4 weeks) and mid-term (up to one year) stability study of CSF stored at 4°C, -20°C, -80°C, and liquid nitrogen. Impact of freeze-thaw cycles, adsorption, and protease inhibitors were tested. RESULTS: The ratio of truncated protein was modified following -20°C storage and seemed to reach a plateau after 6 months. The ratio was impacted neither by freeze-thaw cycles nor adsorption. The -20°C specific cleavage was found to be protease related. CONCLUSION: Using this novel double indirect sandwich ELISA, absolute levels of the total and uncleaved cystatin C and the ratio of truncated cystatin C can be measured. This assay is an easily applicable tool which can be used to confirm that CSF biospecimen are fit-for-purpose for Alzheimer's disease research.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Cistatina C/efeitos adversos , Ensaio de Imunoadsorção Enzimática/normas , Projetos de Pesquisa/normas , Manejo de Espécimes/normas , Humanos , Espectrometria de Massas , Inibidores de Proteases , Estabilidade Proteica
15.
Viruses ; 13(8)2021 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-34452381

RESUMO

The case fatality rate of rabies, nearly 100%, is one of the most unique characteristic of this ancient virus infection. The crucial role rabies virus neutralizing antibody plays in protection is both well established and explanation of why rabies serology is important. Various laboratory methods can and have been used but serum neutralization methods have long been the gold standard due to the ability to measure function (neutralization), however these methods can be difficult to perform for several reasons. Assays such as enzyme linked absorbance assays (ELISA), indirect fluorescence antibody (IFA) and more recently lateral flow methods are in use. Interpretation of results can be problematic, not only between methods but also due to modifications of the same method that can lead to misinterpretations. A common assumption in review of laboratory test results is that different methods for the same component produce comparable results under all conditions or circumstances. Assumptions and misinterpretations provide the potential for detrimental decisions, ranging from regulatory to clinically related, and most importantly what 'level' is protective. Review of the common challenges in performance and interpretation of rabies serology and specific examples illuminate critical issues to consider when reviewing and applying results of rabies serological testing.


Assuntos
Anticorpos Antivirais/sangue , Vírus da Raiva/imunologia , Raiva/diagnóstico , Raiva/imunologia , Testes Sorológicos/normas , Anticorpos Neutralizantes/sangue , Interpretação Estatística de Dados , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Técnica Indireta de Fluorescência para Anticorpo , Testes Hematológicos , Humanos , Testes de Neutralização/métodos , Testes de Neutralização/normas , Vírus da Raiva/isolamento & purificação , Testes Sorológicos/classificação , Testes Sorológicos/métodos
16.
Viruses ; 13(8)2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34452448

RESUMO

Multiple serotypes and topotypes of foot-and-mouth disease virus (FMDV) circulate in endemic areas, posing considerable impacts locally. In addition, introductions into new areas are of great concern. Indeed, in recent years, multiple FMDV outbreaks, caused by topotypes that have escaped from their original areas, have been recorded in various parts of the world. In both cases, rapid and accurate diagnosis, including the identification of the serotype and topotype causing the given outbreaks, plays an important role in the implementation of the most effective and appropriate measures to control the spread of the disease. In the present study, we describe the performance of a range of diagnostic and typing tools for FMDV on a panel of vesicular samples collected in northern Tanzania (East Africa, EA) during 2012-2018. Specifically, we tested these samples with a real-time RT-PCR targeting 3D sequence for pan-FMDV detection; an FMDV monoclonal antibody-based antigen (Ag) detection and serotyping ELISA kit; virus isolation (VI) on LFBKαVß6 cell line; and a panel of four topotype-specific real-time RT-PCRs, specifically tailored for circulating strains in EA. The 3D real-time RT-PCR showed the highest diagnostic sensitivity, but it lacked typing capacity. Ag-ELISA detected and typed FMDV in 71% of sample homogenates, while VI combined with Ag-ELISA for typing showed an efficiency of 82%. The panel of topotype-specific real-time RT-PCRs identified and typed FMDV in 93% of samples. However, the SAT1 real-time RT-PCR had the highest (20%) failure rate. Briefly, topotype-specific real-time RT-PCRs had the highest serotyping capacity for EA FMDVs, although four assays were required, while the Ag-ELISA, which was less sensitive, was the most user-friendly, hence suitable for any laboratory level. In conclusion, when the four compared tests were used in combination, both the diagnostic and serotyping performances approached 100%.


Assuntos
Técnicas de Laboratório Clínico/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Vírus da Febre Aftosa/classificação , Vírus da Febre Aftosa/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sorotipagem/métodos , África Oriental , Animais , Anticorpos Antivirais , Técnicas de Laboratório Clínico/normas , Ensaio de Imunoadsorção Enzimática/normas , Febre Aftosa/virologia , Filogenia , Reação em Cadeia da Polimerase em Tempo Real/normas , Sensibilidade e Especificidade , Sorogrupo , Sorotipagem/normas
17.
Viruses ; 13(7)2021 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-34372525

RESUMO

Zika virus (ZIKV) is a mosquito-borne Flavivirus with a positive-sense RNA genome, which are generally transmitted through the bite of an infected Aedes mosquito. ZIKV infections could be associated with neurological sequelae that, and otherwise produces similar clinical symptoms as other co-circulating pathogens. Past infection with one member of the Flavivirus genus often induces cross-reactive antibodies against other flaviruses. These attributes complicate the ability to differentially diagnose ZIKV infection from other endemic mosquito-borne viruses, making it both a public health issue as well as a diagnostic challenge. We report the results from serological analyses using arbovirus-specific peptides on 339 samples that were previously collected from 6 countries. Overall, we found that our multiplexed peptide-based ELISA was highly efficient for identifying ZIKV antibodies as early as 2 weeks post infection, and that it correlates with microneutralization, plaque reduction neutralization tests (PRNTs) and commercial tests for ZIKV in previously characterized samples. We observed that seropositivity varied by patient cohort, reflecting the sampling period in relation to the 2015-2016 ZIKV outbreak. This work evaluates the accuracy, specificity, and sensitivity of our peptide-based ELISA method for detecting ZIKV antibodies from geographically diverse regions. These findings can contribute to ongoing serological methods development and can be adapted for use in future studies.


Assuntos
Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Peptídeos/imunologia , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/imunologia , Zika virus/imunologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Estudos de Coortes , Reações Cruzadas , Feminino , Ensaios de Triagem em Larga Escala/métodos , Ensaios de Triagem em Larga Escala/normas , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Lactente , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem , Zika virus/química
18.
Viruses ; 13(7)2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-34372604

RESUMO

Dugbe orthonairovirus (DUGV) and Crimean-Congo hemorrhagic fever orthonairovirus (CCHFV) are tick-borne arboviruses within the order Bunyavirales. Both viruses are endemic in several African countries and can induce mild (DUGV, BSL 3) or fatal (CCHFV, BSL 4) disease in humans. Ruminants play a major role in their natural transmission cycle. Therefore, they are considered as suitable indicator animals for serological monitoring studies to assess the risk for human infections. Although both viruses do not actually belong to the same serogroup, cross-reactivities have already been reported earlier-hence, the correct serological discrimination of DUGV and CCHFV antibodies is crucial. In this study, 300 Nigerian cattle sera (150 CCHFV seropositive and seronegative samples, respectively) were screened for DUGV antibodies via N protein-based ELISA, indirect immunofluorescence (iIFA) and neutralization assays. Whereas no correlation between the CCHFV antibody status and DUGV seroprevalence data could be demonstrated with a newly established DUGV ELISA, significant cross-reactivities were observed in an immunofluorescence assay. Moreover, DUGV seropositive samples did also cross-react in a species-adapted commercial CCHFV iIFA. Therefore, ELISAs seem to be able to reliably differentiate between DUGV and CCHFV antibodies and should preferentially be used for monitoring studies. Positive iIFA results should always be confirmed by ELISAs.


Assuntos
Anticorpos Antivirais/sangue , Coinfecção/veterinária , Coinfecção/virologia , Ensaio de Imunoadsorção Enzimática/normas , Vírus da Febre Hemorrágica da Crimeia-Congo/imunologia , Vírus da Doença do Carneiro de Nairobi/imunologia , Doenças Transmitidas por Carrapatos/veterinária , Animais , Bovinos , Doenças dos Bovinos/epidemiologia , Doenças dos Bovinos/virologia , Coinfecção/epidemiologia , Coinfecção/imunologia , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G/sangue , Nigéria/epidemiologia , Ruminantes/imunologia , Ruminantes/virologia , Estudos Soroepidemiológicos , Doenças Transmitidas por Carrapatos/epidemiologia , Doenças Transmitidas por Carrapatos/imunologia , Doenças Transmitidas por Carrapatos/virologia , Carrapatos/virologia
19.
Parasit Vectors ; 14(1): 412, 2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34407876

RESUMO

BACKGROUND: The diagnosis of strongyloidiasis is challenging. Serological tests are acknowledged to have high sensitivity, but issues due to cross-reactions with other parasites, native parasite antigen supply and intrinsic test variability do occur. Assays based on recombinant antigens could represent an improvement. The aim of this study was to assess the sensitivity and specificity of two novel immunoglobulin (Ig)G and IgG4 enzyme-linked immunosorbent assays (ELISAs) based on the recombinant antigens NIE/SsIR for the diagnosis of strongyloidiasis. METHODS: This was a retrospective diagnostic accuracy study. We included serum samples collected from immigrants from strongyloidiasis endemic areas for whom there was a matched result for Strongyloides stercoralis on agar plate culture and/or PCR assay, or a positive microscopy for S. stercoralis larvae. For the included samples, results were also available from an in-house indirect fluorescent antibody test (IFAT) and a commercial (Bordier ELISA; Bordier Affinity Products SA) ELISA. We excluded: (i) samples with insufficient serum volume; (ii) samples from patients treated with ivermectin in the previous 6 months; and (iii) sera from patients for whom only routine coproparasitology was performed after formol-ether concentration, if negative for S. stercoralis larvae. The performance of the novel assays was assessed against: (i) a primary reference standard, with samples classified as negative/positive on the basis of the results of fecal tests; (ii) a composite reference standard (CRS), which also considered patients to be positive who had concordant positive results for the IFAT and Bordier ELISA or with a single "high titer" positive result for the IFAT or Bordier ELISA. Samples with a single positive test, either for the IFAT or Bordier ELISA, at low titer, were considered to be "indeterminate," and analyses were carried out with and without their inclusion. RESULTS: When assessed against the primary reference standard, the sensitivities of the IgG and IgG4 ELISAs were 92% (95% confidence interval [CI]: 88-97%) and 81% (95% CI: 74-87%), respectively, and the specificities were 91% (95% CI: 88-95%) and 94% (95% CI: 91-97%), respectively. When tested against the CRS, the IgG ELISA performed best, with 78% sensitivity (95% CI: 72-83%) and 98% specificity (95% CI: 96-100%), when a cut-off of 0.675 was applied and the indeterminate samples were excluded from the analysis. CONCLUSION: The NIE-SsIR IgG ELISA demonstrated better accuracy than the IgG4 assay and was deemed promising particularly for serosurveys in endemic areas.


Assuntos
Anticorpos Anti-Helmínticos/sangue , Antígenos de Helmintos/genética , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Imunoglobulina G/sangue , Strongyloides stercoralis/imunologia , Estrongiloidíase/diagnóstico , Animais , Antígenos de Helmintos/imunologia , Pré-Escolar , Reações Cruzadas , Humanos , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Estrongiloidíase/sangue , Estrongiloidíase/imunologia
20.
PLoS One ; 16(8): e0256220, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34403457

RESUMO

Zika virus (ZIKV) is a flavivirus that has emerged as a global health threat after the 2015 outbreak in the Americas, where devastating congenital defects were documented. There are currently no vaccines to prevent ZIKV infections nor commercially available clinical diagnostic tests demonstrated to identify ZIKV without cross-reactive interference of related flaviviruses. Early diagnosis is critical when treating symptomatic patients and in preventing ZIKV transmission. In this context, the development of sensitive and accurate diagnostic methods are urgently needed for the detection of ZIKV acute infection. The aim of this study consisted of obtaining monoclonal antibodies (mAbs) against denatured monomeric ZIKV Nonstructural protein 1 (ZNS1), a useful diagnostic marker for flavivirus early detection, in order to develop a highly specific and sensitive ZNS1 indirect competitive ELISA (icELISA). The production of hybridomas secreting ZNS1 mAbs was carried out through immunizations with denatured monomeric ZNS1. We selected 1F5 and 6E2 hybridoma clones, which recognized the heat-denatured ZNS1 hexameric form by indirect ELISA. Cross-reaction studies indicated that these mAbs specifically bind to a ZNS1 linear epitope, and that they do not cross-react with the NS1 protein from other related flaviviruses. The 1F5 mAb enabled the development of a sensitive and reproducible icELISA to detect and quantify small amounts of ZNS1 disease marker in heat-denatured human sera. Here, we establish a reliable 1F5 based-icELISA that constitutes a promising diagnostic tool for control strategies and the prevention of ZIKV propagation.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Antivirais/química , Antígenos Virais/genética , Ensaio de Imunoadsorção Enzimática/métodos , Proteínas não Estruturais Virais/genética , Infecção por Zika virus/diagnóstico , Zika virus/imunologia , Animais , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/isolamento & purificação , Anticorpos Antivirais/biossíntese , Anticorpos Antivirais/isolamento & purificação , Antígenos Virais/administração & dosagem , Antígenos Virais/imunologia , Ligação Competitiva , Clonagem Molecular , Diagnóstico Precoce , Ensaio de Imunoadsorção Enzimática/normas , Escherichia coli/genética , Escherichia coli/metabolismo , Expressão Gênica , Células HEK293 , Humanos , Hibridomas/química , Hibridomas/imunologia , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Multimerização Proteica , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Proteínas não Estruturais Virais/administração & dosagem , Proteínas não Estruturais Virais/imunologia , Zika virus/genética , Infecção por Zika virus/imunologia , Infecção por Zika virus/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...